Support 24/7: (+91)-9789446204 (+91)-8825997098

Features

Comfortable:-

  • Weight adjuster, flexible back ,comfortably places more weight on hips, less weight on shoulders.
  • Available with Velcro Straps.
  • Pocket: Reinforced Belt, Spacious and Strong.
  • Shoulder Pads: Concealed for comfort and durability.

Effective Results:-

  • 0.58mm Lead equivalency (Thyroid Shield Collar)
  • 0.34mm Lead equivalency (lead apron).
  • BARC certified.

Light Weighted:-

  • Length : 98 cm from the shoulder.
  • Breadth : 60 cm.
  • Weight : 2.7 kg.

Easy Usage:-

  • Quick & Easy to use.
  • Soft Fabric.

Description

Waldent Lead Apron & Thyroid Shield Collar constructed of thin rubber and inside have lead in shape of apron.Dental X-rays are an indispensable tool in diagnosis and monitoring oral conditions.It is important that dental lead aprons to be used during such procedure to prevent patient from x – ray exposure.A lead apron is a type of protective clothing that acts as a radiation shield.Lead Apron only attenuate radiation,absobs 90 – 95 % of scattered radiation.

A lead apron is a type of protective barrier that acts as a radiation shield. It is constructed of a thin rubber exterior and an interior of lead.

Thyroid Sheild Collar is type of apron especially designed to protect Thyroid Gland from exposure of X-Rays during Dental Imaging as it is most vulnerable to X-Ray Exposure.

INDICATIONS:

  • To reduce exposure from X-Rays to vital organs that are potentially exposed to ionizing radiation during dental/medical imaging that uses x-rays

BARC Certified (Certificate available)

Key Specifications

Waldent Lead Apron:

  • Weight-2.7kg
  • Length-98cm
  • Width-60cm

Specification Of X-ray Unit Used For Carrying Out The Test : Siemens polydoros – LX with high frequency generator ( max.150 KV, max.800 mA) KV variation : = 1 KV, output variation (COV) : <0.05

Measured Lead Equivalence : 0.34 mm at 100 KVp of X-ray beam.

Waldent Thyroid Sheild Collar:

  • Weight-554gm

Specification Of X-ray Unit Used For Carrying Out The Test : Siemens polydoros – LX with high frequency generator ( max.150 KV, max.800 mA) KV variation : = 1 KV, output variation (COV) : <0.05

Measured Lead Equivalence : 0.58 mm at 100 KVp of X-ray beam.

Packaging

Waldent Lead Apron:

  • 1 x Lead Apron
  • 1 x Hanger

Waldent Thyroid Shield Collar:

  • 1 x Thyroid Shield Collar

 

Additional information

WeightN/A
Size

Waldent Thyroid Shield (Collar)(BARC Approved), Waldent Lead Apron(BARC Approved), Waldent Dental Lead Apron + Thyroid Shield Collar(BARC Approved)

Only logged in customers who have purchased this product may leave a review.