Features
Waldent RTA Intelli-Sensor RVG By Woodpecker Size – 1.5
- High-Resolution Imaging: Achieves a theoretical resolution of 25 lp/mm for clear and detailed images
- C MOS Technology: Utilizes advanced C MOS technology for superior image quality and accuracy
- Thin Design: Features a slim profile with a thickness of just 4.5mm for patient comfort
- Extended USB Cable: Comes with a 2.7m USB cable, allowing for flexible positioning during use
- Durability: Designed to withstand over 80,000 bending tests, ensuring longevity and reliability
- IP68 Protection Rating: Offers high-level protection against dust and water, enhancing the sensor’s durability
- Smart Software: Includes powerful and user-friendly software for efficient image processing and analysis
- Curved Edges: Designed with rounded edges to minimize the risk of patient injury during use
- Flexible Cable: The highly flexible cable allows for easy maneuverability and positioning without compromising durability
Waldent V-Light Pro DC X-ray Machine Combo
- Versatile Solutions: Designed to adapt to various shooting situations, providing flexibility for different dental imaging needs
- Internal Shielding: Features built-in shielding that effectively safeguards against leakage radiation, ensuring safety for both patients and operators
- External Backscatter Shielding: Equipped with external shielding that minimizes operator exposure to radiation during X-ray procedures
- Rechargeable Battery: Includes a rechargeable battery, allowing for cordless operation and enhanced mobility during use
- User-Friendly Interface: Designed with an intuitive control panel that simplifies operation, making it easy for users to navigate settings and functions
- Lightweight Design: Compact and lightweight for easy handling and positioning, improving efficiency in clinical settings
- Enhanced Imaging Quality: Delivers high-quality imaging for accurate diagnostics and treatment planning
Description
Specifications
Waldent RTA Intelli-Sensor RVG By Woodpecker Size – 1.5
- Image Resolution: Ultra-high resolution for clear diagnostics
- User Interface: High-quality, user-friendly interface
- Design: Comfortable and ergonomic design
- Scope of Application: Oral two-dimensional image capturing, case diagnosis, information management
- Operation Mode: Intermittent operation mode
- Electric Shock Protection: BF type applied part
- Water Ingress Protection: IP68
- X-ray Generator Compatibility: Compliant with dental X-ray machine standards
- Power Adapter Input: 5V/USB interface
- Mechanical Size – 1.5 : 43.5*29.2*4.5mm
- Effective Area Size – 1.5 : 24*33mm( Size – 1.5)
- Pixel Size: 20μm
- Effective Resolution: > 12Ip/mm
- Temperature: 10℃ to 35℃
- Humidity: 20% to 90%
- Atmospheric Pressure: 70kPa to 106kPa
Installation Application Specification:
- Operating System: Windows® 7 or above
- Processor: Intel® Core 4
- Memory: 8 GB or above
- Hard Disk: 500 GB or above
- USB Port: 4 high-speed USB 2.0 ports
- USB Chip: Intel or NEC / RENESAS
- Display Resolution: 1920 x 1080
- Software Installation: Run the “Ai-Dental setup.exe” installation program
- Sensor Support Frame Installation: Fixed on flat wall with two screws, Secure sensor on support frame when not in use
Waldent V-Light Pro DC X-ray Machine:
- Tube voltage – 60kV
- Tube current – 2mA
- Focal Spot – 0.4mm
- Exposure Time – 0.01 ~2.00 (Adjustable)
- Anode Angle – 12°
- Source to Skin Distance (SSD) – 211mm ± 3mm (Long) 109mm ± 3mm (Short)
- Total Filtration of X-ray Tube Assembly – >2.5mm Al
- Battery Capacity – 950mAh
- Input Voltage: Uniphasic AC 100-240V, ±10%
- Supply Frequency: 50/60Hz, ±1Hz
- Battery Capacity: 950 mAH battery with polymer high-rate
- Thickness of lead cover on long & short cone is 0.5mm.
The cones have 360° lead covered inside.
Packaging
Waldent V-Light Pro DC X-ray Machine
- 1 x Host
- 1 x Power cable
- 1 x User Manual
- 1 x Adapter
- 1 x Neck Strap
- 1 x Hand Strap
Waldent RTA Intelli-Sensor RVG By Woodpecker Size – 1.5
- 1 x Rvg i Sensor
- 1 x Disposable protective bag
- 1 x Sensor fixer
- 1 x Anti-counterfeiting query label
- 1 x U disk
- 2 x Fixing screw
- 2 x Rubber Stopper
- 1 x Qualified certificate
- 1 x Warranty card
- 1 x Instruction manual
Direct to Use
Waldent RTA Intelli-Sensor RVG By Woodpecker Size – 1.5
System Setup:
- Ensure that the computer meets the specified configuration requirements, including the operating system, processor, memory, USB ports, display board, USB chip, and display resolution
Software Link: Click Here To Download Waldent RTA Intelli – Sensor RVG Software - Run the “Ai-Dental setup.exe” installation program and follow the on-screen instructions to install the image management software system
Sensor Installation:
- Fix the sensor support frame on a flat wall using two screws
- When the sensor is not in use, secure it on the support frame
Imaging Process:
- Turn on the PC with the installed image processing software
- Start the matching X-ray generator and set the desired photographing parameters
- Put on a disposable protective sheath on the sensor
- Place the sensor in the patient’s mouth parallel to the long axis of the teeth, ensuring the effective surface of the sensor is close to the teeth
X-ray Capture:
- Move the X-ray generator to the patient’s head, ensuring the generator cone is perpendicular to the sensor’s position
- Press the generator switch to capture the X-ray image
- After exposure, the imaging software downloads the X-ray image for display on the screen
Sensor Protective Sheath Usage:
- Wear gloves when placing the disposable sensor protective sheath
- Replace the protective sheath after each use and dispose of it with other potentially infectious waste
- Store the used sheaths in a dry and clean place
Waldent V-Light Pro DC X-ray Machine
Power Connection:
- Ensure the input voltage is within the specified range (Uniphasic AC 100-240V)
- Connect the machine to a power source using the provided power adapter
- Confirm that the supply frequency is 50/60Hz
Charging:
- Open the cover and insert the adapter charging cable into the adapter connection port to charge the internal battery
Positioning:
- Place the machine in a clean, dry, and well-ventilated room, following the specified zone of significant occupancy (as shown in the provided figure)
Patient and Operator Safety:
- Ensure the operator is present in the designated zone during operation
- Verify that the height and area of the significant occupancy zone meet the requirements (no less than 60cm x 60cm, with a height of no less than 200cm)
Exposure Switch Connection:
- Open the cover and insert the exposure switch into the exposure switch connection port for seamless operation
Operation:
- Utilize the intuitive operation panel for user-friendly control
- Adjust the settings as needed, considering factors such as tube voltage, tube current, and loading time
Image Acquisition:
- Position the X-ray tube assembly appropriately for the desired imaging area
- Activate the exposure switch to initiate the X-ray process
Maintenance:
- Regularly clean and maintain the equipment to ensure optimal performance
- Do not attempt to modify the equipment without contacting the manufacturer
Safety Precautions:
- Follow all safety guidelines provided in the user manual
- If in doubt or if modifications are required, contact the manufacturer for assistance
Warranty
Waldent RTA Intelli-Sensor RVG By Woodpecker Size – 1.5
- Manufacturer/Importer warranty of 5 Years as applicable for this product
- Warranty does not apply against any physical damage to the product
- Service and Warranty are handled by the manufacturer/importer directly for this product
- Alpha Dentkart will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
- Alpha Dentkart and the Buyer acknowledge that the Products purchased/used are a subject matter of the original Manufacturer/Importer’s warranties only
- Any or all claims in relation to returns and replacement shall be made to the concerned Manufacturer/Importer only and Alpha Dentkart may assist the customer in registering a request to get the Product replaced or serviced.
- The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be.
Reviews
There are no reviews yet.