Features
- Class 5 chemical indicator (ISO 11140-1 compliant)
- Monitors time
- temperature
- and steam saturation in sterilization
- Effective at 121°C to 135°C sterilization cycles
- Validated for 121°C (15 minutes) and 134°C (3.5 minutes) pre-vacuum cycles
- Clear color change from yellow to black for easy result interpretation
- Lead-free and free from toxic heavy metals
- Strip size: 15mm x 75mm
- Suitable for medical
- dental
- and laboratory sterilization monitoring
Description
Riverside Type 5 Steam Integrator Strips, available in a pack of 400, are essential tools for monitoring sterilization processes in pre-vacuum steam sterilizers. Designed to ensure optimal sterilization conditions, these strips are free from lead and other toxic heavy metals, making them a safe choice for health and safety applications. They function by integrating critical variables—time, temperature, and moisture—into a single indicator. This comprehensive reaction aligns with the performance of a biological indicator (BI) at specific exposure levels, providing a reliable measure of whether sterilization conditions have been met. The Riverside Type 5 strips are effective in steam sterilizers operating at temperatures ranging from 121°C to 135°C, making them versatile for various sterilization needs. Each strip is engineered to give clear and accurate results, ensuring that every cycle meets the stringent standards required for effective sterilization. Ideal for medical, laboratory, and industrial settings, these integrator strips offer peace of mind by confirming that sterilization parameters have been adequately achieved.
Key Specifications
- Sterilizer Type: Pre-vacuum steam sterilizers
- Temperature Range: 121°C to 135°C
- Indicator Type: Type 5 Integrating Indicator
- Critical Variables Monitored: Time, temperature, and moisture
- Indicator Strip Dimension: 15mm x 75mm
Packaging
- 1 x Type 5 Steam Integrator Strips (Pack of 400)
Direction to Use
- Preparation: Ensure that the sterilizer is properly set up and ready for use. Verify that the machine is functioning according to the manufacturer’s specifications.
- Placement: Insert a Riverside Type 5 Steam Integrator Strip into the sterilization load. Place the strip in a location that will be exposed to the steam and heat throughout the entire sterilization cycle.
- Run Cycle: Start the sterilization cycle as per the sterilizer’s instructions. Ensure that the cycle conditions meet the required parameters for effective sterilization (temperature and duration).
- Post-Cycle Inspection: After the cycle is complete, remove the strip from the load and inspect the color change on the strip. The indicator should show a color change that corresponds to successful sterilization according to the strip’s Stated Values.
- Interpret Results: Compare the color change to the provided reference chart or guidelines to determine if the sterilization conditions were met. The strip’s performance should correlate with a biological indicator (BI) for the specific time/temperature exposure.
- Documentation: Record the results as part of your sterilization monitoring and documentation procedures.
- Dispose: Properly dispose of used strips in accordance with your facility’s waste disposal protocols.