Features
- High-resolution imaging – 25lp/mm theoretical resolution
- C Mos Technology
- Thinnest sensor 4.5mm
- USB cable – 2.7m
- Durable and reliable: 80000+ bending test & IP68 protection rating
- Smart and powerful software
- Curved Edges to Avoid Patient Injury
- Highly Flexible Cable
Descriptions
Waldent RTA i-Sensor RVG by Woodpecker is a state-of-the-art dental imaging solution designed to streamline radiographic procedures and enhance diagnostic precision. This Radiovisiography (RVG) system integrates seamlessly into dental practices, offering exceptional image quality and ease of use. The sensor boasts an ultra-thin profile and ergonomic design for patient comfort and precise placement. With advanced sensor technology, it captures X-ray radiation and converts it into high-resolution digital images for detailed analysis. The accompanying monitor provides real-time visualization of images, empowering dentists to make informed treatment decisions efficiently. Built with durability and reliability in mind, this RVG system ensures consistent performance, while its IP68 rating protects against dust and liquid ingress for long-lasting use. Experience the future of dental imaging with the Waldent RTA i-Sensor RVG by Woodpecker, where innovation meets excellence for superior patient care.
Specifications
- Image Resolution: Ultra-high resolution for clear diagnostics
- User Interface: High-quality, user-friendly interface
- Design: Comfortable and ergonomic design
- Scope of Application: Oral two-dimensional image capturing, case diagnosis, information management
- Operation Mode: Intermittent operation mode
- Electric Shock Protection: BF type applied part
- Water Ingress Protection: IP68
- X-ray Generator Compatibility: Compliant with dental X-ray machine standards
- Power Adapter Input: 5V/USB interface
- Mechanical Size – 1 : 38.5*25*4.5mm
- Mechanical Size – 1.5 : 43.5*29.2*4.5mm
- Mechanical Size – 2 : 45.0*31.6*4.5mm
- Effective Area Size- 1 : 20*30mm( Size – 1 )
- Effective Area Size – 1.5 : 24*33mm( Size – 1.5)
- Effective Area Size – 2: 26*36mm( Size – 2)
- Pixel Matrix Size -1: 1000*1500( Size-1)
- Pixel Matrix Size -1.5: 1200*1650( Size – 1.5)
- Pixel Matrix Size -2: 1300*1800mm( Size – 2)
- Pixel Size: 20μm
- Effective Resolution: > 12Ip/mm
- Temperature: 10℃ to 35℃
- Humidity: 20% to 90%
- Atmospheric Pressure: 70kPa to 106kPa
Installation Application Specification:
- Operating System: Windows® 7 or above
- Processor: Intel® Core 4
- Memory: 8 GB or above
- Hard Disk: 500 GB or above
- USB Port: 4 high-speed USB 2.0 ports
- USB Chip: Intel or NEC / RENESAS
- Display Resolution: 1920 x 1080
- Software Installation: Run the “Ai-Dental setup.exe” installation program
- Sensor Support Frame Installation: Fixed on flat wall with two screws, Secure sensor on support frame when not in use
Packaging
- 1 x Rvg i Sensor
- 1 x Disposable protective bag
- 1 x Sensor fixer
- 1 x Anti-counterfeiting query label
- 1 x U disk
- 2 x Fixing screw
- 2 x Rubber Stopper
- 1 x Qualified certificate
- 1 x Warranty card
- 1 x Instruction manual
Software Link: Click Here To Download Waldent RTA I-Sensor RVG Software
Direction to Use
Here are the directions for using the Waldent RTA i-Sensor RVG:
System Setup:
- Ensure that the computer meets the specified configuration requirements, including the operating system, processor, memory, USB ports, display board, USB chip, and display resolution.
Software Link: Click Here To Download Waldent RTA I-Sensor RVG Software - Run the “Ai-Dental setup.exe” installation program and follow the on-screen instructions to install the image management software system.
Sensor Installation:
- Fix the sensor support frame on a flat wall using two screws.
- When the sensor is not in use, secure it on the support frame.
Imaging Process:
- Turn on the PC with the installed image processing software.
- Start the matching X-ray generator and set the desired photographing parameters.
- Put on a disposable protective sheath on the sensor.
- Place the sensor in the patient’s mouth parallel to the long axis of the teeth, ensuring the effective surface of the sensor is close to the teeth.
X-ray Capture:
- Move the X-ray generator to the patient’s head, ensuring the generator cone is perpendicular to the sensor’s position.
- Press the generator switch to capture the X-ray image.
- After exposure, the imaging software downloads the X-ray image for display on the screen.
Sensor Protective Sheath Usage:
- Wear gloves when placing the disposable sensor protective sheath.
- Replace the protective sheath after each use and dispose of it with other potentially infectious waste.
- Store the used sheaths in a dry and clean place.
Warranty
- Manufacturer/Importer warranty of 5 Years as applicable for this product
- Warranty does not apply against any physical damage to the product
- Service and Warranty are handled by the manufacturer/importer directly for this product
- Alpha Dentkart will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
- Alpha Dentkart and the Buyer acknowledge that the Products purchased/used are a subject matter of original Manufacturer/Importer’s warranties only
- Any or all claims in relation to returns and replacement shall be made to the concerned Manufacturer/Importer only and Alpha Dentkart may assist the customer in registering a request to get the Product replaced or serviced.
- The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be.
Reviews
There are no reviews yet.